8QCM

ABCG2 in complex with MZ82 and 5D3 Fab


ELECTRON MICROSCOPY

Starting Model(s)

Initial Refinement Model(s)
TypeSourceAccession CodeDetails
experimental modelPDB 6FFC 

Refinement

RMS Deviations
KeyRefinement Restraint Deviation
f_dihedral_angle_d13.3975
f_angle_d0.6743
f_chiral_restr0.0454
f_bond_d0.007
f_plane_restr0.0042
Sample
ABCG2 in complex with MZ82 and 5D3 Fab
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification InstrumentFEI VITROBOT MARK IV
Cryogen NameETHANE-PROPANE
Sample Vitrification DetailsGrids were blotted for 2.5s with blot force 1
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles601814
Reported Resolution (Å)2.39
Resolution MethodFSC 0.143 CUT-OFF
Other Details
Refinement Type
Symmetry TypePOINT
Point SymmetryC1
Map-Model Fitting and Refinement
Id1 (6ffc)
Refinement Space
Refinement ProtocolRIGID BODY FIT
Refinement Target
Overall B Value
Fitting Procedure
Details
Data Acquisition
Detector TypeGATAN K3 BIOQUANTUM (6k x 4k)
Electron Dose (electrons/Å**2)42
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelFEI TITAN KRIOS
Minimum Defocus (nm)800
Maximum Defocus (nm)2200
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS2.7
Imaging ModeBRIGHT FIELD
Specimen Holder ModelFEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification130000
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging Details
EM Software
TaskSoftware PackageVersion
IMAGE ACQUISITIONEPU2
CTF CORRECTIONcryoSPARC3
MODEL FITTINGUCSF Chimera
FINAL EULER ASSIGNMENTcryoSPARC3
CLASSIFICATIONcryoSPARC3
RECONSTRUCTIONcryoSPARC3
MODEL REFINEMENTPHENIX
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION