8R3Y

Cryo EM structure of a stable LGL/aPKC Iota/Par-6 complex


ELECTRON MICROSCOPY

Starting Model(s)

Initial Refinement Model(s)
TypeSourceAccession CodeDetails
experimental modelPDB THIS STUDY 
experimental modelPDB 1NF3 
experimental modelPDB 6N8Q 

Refinement

RMS Deviations
KeyRefinement Restraint Deviation
f_dihedral_angle_d13.279
f_angle_d3.576
f_chiral_restr0.158
f_bond_d0.039
f_plane_restr0.03
Sample
aPKCiota-Par6-Llgl1 complex
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification InstrumentFEI VITROBOT MARK IV
Cryogen NameETHANE
Sample Vitrification Details4 ul of aPKCiota-Par6-Llgl1 complex at a concentration of 0.4 mg/ml was applied to R1.2/1.3 Quantifoil 300 mesh copper grids which had been glow-disch ...4 ul of aPKCiota-Par6-Llgl1 complex at a concentration of 0.4 mg/ml was applied to R1.2/1.3 Quantifoil 300 mesh copper grids which had been glow-discharged for 45 s at 45 mA . Grids were blotted for 2.5 s at 100% humidity using an FEI Vitrobot MK IV.
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles121194
Reported Resolution (Å)3.68
Resolution MethodFSC 0.143 CUT-OFF
Other Details
Refinement Type
Symmetry TypePOINT
Point SymmetryC1
Map-Model Fitting and Refinement
Id1 (8R3X, 1NF3, 6N8Q)
Refinement SpaceREAL
Refinement ProtocolFLEXIBLE FIT
Refinement Target
Overall B Value
Fitting Procedure
DetailsInitial fitting was done in Chimera. Interactive Model building was done in COOT & Isolde Refinement was done using Phenix.
Data Acquisition
Detector TypeGATAN K2 SUMMIT (4k x 4k)
Electron Dose (electrons/Å**2)48.1
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelFEI TITAN KRIOS
Minimum Defocus (nm)1200
Maximum Defocus (nm)3000
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS
Imaging ModeBRIGHT FIELD
Specimen Holder ModelFEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging Details
EM Software
TaskSoftware PackageVersion
PARTICLE SELECTIONXmipp3
PARTICLE SELECTIONGautomatch
PARTICLE SELECTIONRELION3
CTF CORRECTIONCTFFIND2
MODEL FITTINGUCSF Chimera
MODEL FITTINGCoot0.9.8
MODEL FITTINGISOLDE
RECONSTRUCTIONcryoSPARC2
MODEL REFINEMENTPHENIX
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING ONLY1069057Semi-automated picking with Xmipp3 and particle extraction in Relion-3 yielded 47,516 particles from 1000 micrographs 38. After reference-free 2D classification in Relion-3, eight 2D classes were selected and used as templates for reference-based particle picking in Gautomatch. A total of particles were extracted with 2-fold binning and submitted to 8 rounds of 2D classification in Relion-3.