8C4S

Apo Hantaan virus polymerase core


ELECTRON MICROSCOPY
Sample
Apo Hantaan virus polymerase core
Specimen Preparation
Sample Aggregation StatePARTICLE
Vitrification InstrumentFEI VITROBOT MARK IV
Cryogen NameETHANE
Sample Vitrification Details
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles105717
Reported Resolution (Å)3.27
Resolution MethodFSC 0.143 CUT-OFF
Other Details
Refinement Type
Symmetry TypePOINT
Point SymmetryC1
Map-Model Fitting and Refinement
Id1
Refinement SpaceREAL
Refinement ProtocolAB INITIO MODEL
Refinement Target
Overall B Value65.75
Fitting Procedure
Details
Data Acquisition
Detector TypeGATAN K2 SUMMIT (4k x 4k)
Electron Dose (electrons/Å**2)50
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelTFS GLACIOS
Minimum Defocus (nm)800
Maximum Defocus (nm)800
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS2.7
Imaging ModeBRIGHT FIELD
Specimen Holder ModelFEI TITAN KRIOS AUTOGRID HOLDER
Nominal Magnification36000
Calibrated Magnification43668
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)200
Imaging Details
EM Software
TaskSoftware PackageVersion
PARTICLE SELECTIONcryoSPARC3.3.2
IMAGE ACQUISITIONSerialEM
CTF CORRECTIONcryoSPARC3.3.2
CTF CORRECTIONRELION4.0
MODEL FITTINGCoot0.9.2
INITIAL EULER ASSIGNMENTcryoSPARC3.3.2
FINAL EULER ASSIGNMENTRELION4.0
CLASSIFICATIONRELION4.0
RECONSTRUCTIONRELION4.0
MODEL REFINEMENTPHENIX1.20.1
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION1116690