8RHH

Microtubule-associated kinesin-1 tail complex bound to AMPPNP, two-headed state


ELECTRON MICROSCOPY

Refinement

RMS Deviations
KeyRefinement Restraint Deviation
f_dihedral_angle_d11.89
f_angle_d0.728
f_chiral_restr0.046
f_bond_d0.004
f_plane_restr0.004
Sample
13pf microtubule bound to Kif5bMoNeIAK in the presence of AMPPNP (two-headed state)
Sample Components
Kinesin-1 heavy chain
13pf microtubule
Specimen Preparation
Sample Aggregation StateFILAMENT
Vitrification InstrumentLEICA EM GP
Cryogen NameETHANE
Sample Vitrification Details
3D Reconstruction
Reconstruction MethodSINGLE PARTICLE
Number of Particles570836
Reported Resolution (Å)3
Resolution MethodFSC 0.143 CUT-OFF
Other DetailsRelion noise-substitution test corrected FSC
Refinement Type
Symmetry TypePOINT
Map-Model Fitting and Refinement
Id1
Refinement SpaceREAL
Refinement ProtocolFLEXIBLE FIT
Refinement Target
Overall B Value
Fitting Procedure
DetailsPhenix Real Space refine and Coot
Data Acquisition
Detector TypeGATAN K3 (6k x 4k)
Electron Dose (electrons/Å**2)52
Imaging Experiment1
Date of Experiment
Temperature (Kelvin)
Microscope ModelTFS KRIOS
Minimum Defocus (nm)700
Maximum Defocus (nm)2500
Minimum Tilt Angle (degrees)
Maximum Tilt Angle (degrees)
Nominal CS
Imaging ModeBRIGHT FIELD
Specimen Holder Model
Nominal Magnification
Calibrated Magnification
SourceFIELD EMISSION GUN
Acceleration Voltage (kV)300
Imaging Details
EM Software
TaskSoftware PackageVersion
PARTICLE SELECTIONRELION3.0
IMAGE ACQUISITIONEPU
CTF CORRECTIONCTFFIND
FINAL EULER ASSIGNMENTRELION
CLASSIFICATIONRELION
RECONSTRUCTIONRELION
Image Processing
CTF Correction TypeCTF Correction DetailsNumber of Particles SelectedParticle Selection Details
PHASE FLIPPING AND AMPLITUDE CORRECTION